Gets/sets the enable [value] of the external stop functionality.


Access: Read/Write

Category: General

Applies to: All Commander Controllers

Firmware: V301+


ASCII                EXSTP


Syntax        

               

Read

EXSTP

       

Write

EXSTP=[value]                 

[value] is set to:

0: External stop disabled, 

1: External Decelerate-stop enabled (same as STOP command), or

2: External stop immediately enabled (same as ABORT)


Reply 

Command is accepted and executed


Read         

Returns enable/disable status, 0 = disabled, 1= enabled


Write           

OK


Command cannot be processed

       An error message is returned. See Error Codes


Example 

Read  

EXSTP        * Returns the external stop status

Write

EXSTP=0         * Disables the external stop function 


Notes

Added with V301 firmware.


See also

System Setup, Limits/Safety Setup, 

ERC, ERCD, ERCP, INP, POL, SDC, SDE, IERR, STORE


Commander Manual

Synchronization with external trigger

External Start