Gets/sets the output pulse width [value] of the deviation counter clear signal for [axis].


Access: Read/Write

Category: Servo

Applies to: All Commander Controllers


ASCII                ERCP[axis]


Syntax        

               

Read

ERCP[axis]                

[axis] is set to X, Y, Z, U


Write

ERCP[axis]=[value]        

[axis]   is set to X, Y, Z, U,

[value]   Set the output pulse width (0-7)

               0: 12 us

               1: 102 us

               2: 409 us

               3: 1.6 ms

               4: 13 ms

               5: 52 ms

               6: 104 ms

               7: Level output


Reply

Command is accepted and executed


Read         

Returns the value set for output pulse width (0-7)


Write           

OK


Command cannot be processed

       An error message is returned. See Error Codes


Example 

Read  

ERCPY        * Returns the setting for the output pulse width for the Y-axis

Write  

ERCPZ=5         * Sets Z-axis deviation counter clear signal output pulse width to 52 ms


Notes

See picture to understand interaction of error signal, ERC signal and the ERCD and ERCP settings.


See also

Motor Setup

ERC, ERCD, INP, POL, SDC, SDE, EXST, IERR, STORE


Commander Manual

Digital Servo