Gets/sets the output pulse width [value] of the deviation counter direction signal for [axis].

Access: Read/Write

Category: Servo

Applies to: All Commander Controllers

ASCII                ERCD[axis]

Syntax                        

Read

ERCD[axis]                

Where:        [axis] is set to X, Y, Z, U


Write

ERCD[axis]=[delay]         

Where:        [axis]  is set to X, Y, Z, U

[delay]   sets the OFF delay time (0-3)

               0: 0 us

               1: 12 us

               2: 1.6 ms

               3: 104 ms

Reply

Command is accepted and executed

Read         

Returns the value set for delay time (0-3)

Write           

OK


Command cannot be processed

       An error message is returned. See Error Codes

Example 

Read  ERCDY        * Returns the setting for the OFF delay time for the Y-axis

Write        ERECZ=3 * Sets Z-axis deviation counter clear signal OFF delay time to 104 ms


Notes

See picture to understand interaction of error signal, ERC signal and the ERCD and ERCP settings.

See also

Motor Setup

ERC, ERCP, INP, POL, SDC, SDE, EXST, IERR, STORE

Commander Manual

2.1.2.2 Digital Servo