Gets/sets the output pulse width [value] of the deviation counter direction signal for [axis].


Access: Read/Write

Category: Servo

Applies to: All Commander Controllers


ASCII                ERCD[axis]


Syntax        

               

Read

ERCD[axis]                

[axis] is set to X, Y, Z, U


Write

ERCD[axis]=[value]

[axis]  is set to X, Y, Z, U

[value]   sets the OFF delay time (0-3)

               0: 0 us

               1: 12 us

               2: 1.6 ms

               3: 104 ms


Reply

Command is accepted and executed


Read         

Returns the value set for delay time (0-3)


Write           

OK


Command cannot be processed

       An error message is returned. See Error Codes


Example 

Read  

ERCDY        * Returns the setting for the OFF delay time for the Y-axis

Write        

ERECZ=3 * Sets Z-axis deviation counter clear signal OFF delay time to 104 ms


Notes

See image to understand interaction of error signal, ERC signal and the ERCD and ERCP settings.


See also

Motor Setup

ERC, ERCP, INP, POL, SDC, SDE, EXST, IERR, STORE


Commander Manual

Digital Servo