Description

Error Code

Used with:

CMD-4CR

PMX-4EX

PMX-4ET

PMX-2ED

PMX-2EX

ASCII command is not recognized

?Unknown Command: [Command]

●





?[Command]


●

●

●

●

Move command could not be processed. One of more of the required axes may be in an error state or in motion

?Error Moving

●





Move command could not be processed. Alarm signal is in the on state

?Error Alarm

●





?ALARM


●

●



Move command could not be processed;
(+) End Limit is in the on state or (-) End Limit is in the on state

?Error +Limit

●





?Error -Limit

●





?LIMIT


●

●



Move command could not be processed. EMG signal is in the on state

?Error ESTOP

●





Move command could not be processed. StepNLoop control is in error state

?Error SNL

●





Index number is invalid

?Invalid Index

●





Command cannot be processed; a standalone program is in an error state

?Program Error

●





Call to subroutine using the GS command is not valid, specified subroutine has not been defined

?Sub not initialized

●

●

●

●

●

Move can not be added to a buffer register; all registers are full

?Buffer Full

●





?BUFFER FULL


●

●



Buffer command is not valid; buffer mode is disabled

?Buffer Disabled

●





?BUFOFF



●



SSPD command cannot be processed; buffer mode is enabled

?Buffer Enabled

●





?BUFON



●



SSPD command cannot be processed; SSPD mode is not defined, out of range, or S-curve is enabled

?SSPD Error

●

●




?SSPD mode not initialized



●

●

●

?Bad SSPD Command



●



?Speed out of range



●

●

●

?S-curve on



●

●

●

T[ ] command is invalid because a target position move is not in operation

?ABS/INC is not in operation




●

●

A move command has been issued while the axis is in StepNLoop error

?Clear SNL Error




●

●

Override operation failed

?Override Failed






An attempt to set the timer register while it is running has been made

?Timer Running


●

●



A command has been issued while in an error state

?ERRORED


●




?StatError



●



A circle or arc interpolation move has been issued while the controller is in incremental mode

?In Incremental mode


●

●



The index for the command sent to the controller is not valid.

?Index out of range


●

●

●

●

A move or position change command is sent while the controller is outputting pulses

?PULSING


●

●



?Moving




●

●

On-the-fly speed change attempted during an interpolated move

?ICommandOn




●

●

Invalid parameter input

?Invalid Answer




●

●

Low speed parameter is out of range

?Low speed out of range




●

●

The setting for SFLN is larger or equal to SFLP

?SoftLimit values not valid

●





The setting for SFLSO is not set to a valid input for Soft-limits

?SoftLimit source not valid

●





The value set for SYNMIN was larger than the value set for SYNMAX

?SYNMIN > SYNMAX

●