STORE – Save System Settings
Write-only command to save the setting value of various system settings to flash memory.
Applies to: CMD-4CR, CMD-4EX-SA
ASCII/Standalone STORE global acceleration setting
Syntax:
Write:
STORE
| There is no parameter to specify. | 
The items shown in the table below are stored to flash by issuing the STORE command.
| ASCII Commands | Description | 
|  | AntiCollision | 
| DB | Serial communication baud rate | 
| DIP | Digital input polarity | 
| DOBOOT | DO configuration at boot-up | 
| DOP | Digital output polarity | 
| EINT | Linear interpolation feature | 
| EOBOOT | EO configuration at boot-up | 
| ERC[axis], ERCP[axis],ERCD[axis] | Deviation counter parameters | 
| EXST | External start feature | 
| ID | Identification number | 
| IERR | Ignore Error State | 
| INP[axis] | In position feature enable | 
| IOBOOT | Configurable IO status at boot-up | 
| IOCFG | IO configuration | 
| IOP | Configurable IO polarity | 
| JENA , JMAX[axis], JMIN[axis], JDEL[axis], JTOL[axis], JSPD[axis], JLIM[ch] | Joystick parameters | 
| JKA[axis], JKD[axis] | Jerk Control / S-curve percentage | 
| MPE[axis], MPM[axis], MPD[axis] | Manual pulsar parameters | 
| POL[axis] | Polarity settings | 
| SAP | Jump return line select (Standalone error handling) | 
| SCV[axis] | S-curve enable | 
| SDE[axis], SDC[axis] | Deceleration Signal parameters | 
| SFL[axis], SFLSO[axis], SFLP[axis], SFLN[axis], SFLSD[axis] | Soft-Limit parameters | 
| SL[axis], SLR[axis], SLE[axis], SLT[axis], SLA[axis] | StepNLoop parameters | 
| SLOAD | Standalone program run on boot-up parameter | 
| V0-V99 | Standalone variables | 
| ZCNT[axis] |  | 
Reply:
Command is accepted and executed
Write:
OK
Command cannot be processed
An error message is returned. See Error Codes
Example:
Write:
STORE * Stores select system settings to flash memory.
Notes:
- None
See also:
Limits/Safety Setup, System Setup, I/O Setup,
ERC, ERCD, ERCP, INP, POL, SDC, SDE, EXST, IERR
Commander Manual
2.1.3.2.2 High-Speed Digital Output