ERCP – Deviation Counter Clear Pulse Width
Sets the output pulse width of the deviation counter clear signal.
Applies to: CMD-4CR, CMD-4EX-SA
ASCII ERCP[axis]
Syntax:
Read:
ERCP[axis]
Where: [axis] is set to X, Y, Z, U |
Write:
ERCP[axis]=[outpls]
Where: [axis] is set to X, Y, Z, U, [outpls] Set the output pulse width (0-7) 0: 12 us 1: 102 us 2: 409 us 3: 1.6 ms 4: 13 ms 5: 52 ms 6: 104 ms 7: Level output |
Reply:
Command is accepted and executed
Read:
Returns the value set for output pulse width (0-7).
Write:
OK
Command cannot be processed
An error message is returned. See Error Codes
Example:
Read:
ERCPY * Returns the setting for the output pulse width for the Y-axis
Write:
ERCPZ=5 * Sets Z-axis deviation counter clear signal output pulse width to 52 ms
Notes:
- See picture to understand interaction of error signal, ERC signal and the ERCD and ERCP settings.
See also:
ERC, ERCD, INP, POL, SDC, SDE, EXST, IERR, STORE