Read/write command that returns or sets the polarity of outputs.


Applies to: CMD-4CR, CMD-4EX-SA, PMX-4EX-SA, PMX-4ET-SA


ASCII/Standalone                DOP

Syntax:                        

Read:

DOP                

Write:

DOP=[pol]                 

Where:        [pol] is set to 0 for negative logic(active low), 1 for positive logic (active high).

Reply: 

Command is accepted and executed

Read:         

Returns the value set (0, 1).


Write:           

OK


Command cannot be processed

       An error message is returned. See Error Codes

Example: 

Read:        

DOP                * Returns value for output polarity setting


Write:        

DOP=1         * Set output polarity to 1 (positive logic [active high]).


Notes:

  • To write the value to the device’s flash memory, use the STORE command.

See also:

I/O Setup

AI, DI, DIP, DO, DOBOOT, IO, IOBOOT, IOCFG, IOP

Commander Manual

2.1.3.2.2 High-Speed Digital Output