Read/write command that toggles the polarity of inputs.


Applies to: CMD-4CR, CMD-4EX-SA, PMX-4EX-SA, PMX-4ET-SA


ASCII                        DIP=[pol]                

Syntax:                        

Read:

DIP                

Write:

DIP=[pol]                 

Where:        [pol] is set to 0 for negative logic (active low), 1 for positive logic (active high).

Reply: 

Command is accepted and executed

Read:         

Returns the value set (0,1).


Write:           

OK


Command cannot be processed

       An error message is returned. See Error Codes

Example: 

Read:        

DIP                * Returns value for input polarity setting


Write:        

DIP=1         * Set input polarity to 1.


Notes:

  • To write the value to the device’s flash memory, use the STORE command.

See also:

I/O Setup

AI, DI, DO, DOBOOT, DOP, IO, IOBOOT, IOCFG, IOP

Commander Manual

2.1.3.2.1 High-Speed Digital Inputs