SR Standalone - [prgNo]
Gets/sets the standalone [prgNo], stop(0), start(1), pause(2), and continue(3)
This command obtains a line number in a standalone program that is being executed. The line number here is the number of the Assembly code. It is different from the line number that is actually written.
Access: Read/Write
Category: Standalone
Applies to: All Commander Controllers
ASCII SR
Syntax
Read
SR[axis]
|
[axis] specifies the axis (X, Y, Z, U) |
Write
SR[axis]=[value]
|
[axis] specifies the axis to be set (X, Y, Z, U) [value] specifies if the standalone [prgNo] 0: Stop 1: Start 2: Pause 3: Continue |
Reply
Command is accepted and executed
Read
Returns the value set for standalone program start (0-3)
Write
OK
Command cannot be processed
An error message is returned. See Error Codes
Example
Read
SRX * Returns the [prgNo] for the X-axis
Write
SRZ=1 * Sets z-axis to start on power up
Notes
None
See also
SACTRL, SAP, SASTAT, SLOAD, V, GS, SPC