Gets/sets the source [value] for the soft-limit function on [axis].

Access: Read/Write

Category: Motion

Applies to: All Commander Controllers


ASCII                SFLSO[axis]

Syntax                        

Read

SFLSO[axis]                

[axis] is set to X, Y, Z, U


Write

SFLSO[axis]=[value]                 

[axis] is set to X, Y, Z, U

[value] encoder counter (1) or pulse generator counter (0) 


Reply 

Command is accepted and executed


Read         

Returns 1 for the encoder counter or 0 if pulse generator counter is the source for the the soft-limit axis position


Write           

OK


Command cannot be processed

       An error message is returned. See Error Codes


Example 

Read        

SFLSOY        * Returns source for the the soft-limit axis position for the Y axis 

Write        

SFLSOX=1         * Sets the encoder counter as the source for the the soft-limit axis position for the X axis.


Notes

It is safest to use the encoder counter if an encoder is available, as it will allow the tracking of the motor even if an outside force moves the motor. 


See also

Limits/Safety Setup, 

SFL, SFLP, SFLN, SFLSD


Commander Manual

Soft-Limits