Gets/sets the StepNLoop enable [value] for [axis].


Access: Read/Write

Category: Stepnloop

Applies to: All Commander Controllers


ASCII/Standalone                SL        

       

Syntax

                       

Read

SL[axis]                

[axis] specifies the axis to be enabled/disabled (X, Y, Z, U)


Write

SL[axis]=[value], SL=[value]                

[axis] specifies the axis to be enabled/disabled (X, Y, Z, U)

[value] specify 0 to disable or 1 to enable


Reply 

Command is accepted and executed


Read         

Returns the enable/disable status (0 – disabled, 1 – enabled)


Write           

OK


Command cannot be processed

       An error message is returned. See Error Codes


Example 

Read        

SLY        * Returns the value (0, 1) of the Y-axis

Write        

SLX=1 * Enables StepNLoop function for the X-axis


Notes

Joystick and buffer operation are invalid during StepNLoop operation


See also

StepNLoop

SLA, SLE, SLR, SLRA, SLS, SLT

 

Commander Manual

StepNLoop Closed Loop Control operation