SFLN – Negative Soft-limit setting
Gets/sets the [value] for the negative soft-limit on [axis].
Access: Read/Write
Category: Motion
Applies to: All Commander Controllers
ASCII SFLN[axis]
Syntax
Read
SFLN[axis]
|
[axis] is set to X, Y, Z, U |
Write
SFLN[axis]=[value]
|
[axis] is set to X, Y, Z, U [value] specifies target of negative soft-limit (28-bit value) |
Reply
Command is accepted and executed
Read
Returns the comparator value of the [axis] negative direction soft-limit (28-bit value)
Write
OK
Command cannot be processed
An error message is returned. See Error Codes
Example
Read
SFLNY * Returns the comparator value of the Y axis negative direction soft-limit
Write
SFLNX=-6000 * Sets X axis negative direction soft-limit to -6000
Notes

- Before enabling soft-limits, check that softLimitPositive SFLP[axis] and softLimitNegative SFLN[axis] are different and that the positive value is greater than the negative value. If not, an error is returned.
- Soft-limits act similarly to limit switches. While the controller will command a stop when a soft-limit is encountered, it is possible to overrun the soft limit. The amount the system can overrun the limit depends on the speed the motor is moving at when the soft-limit is encountered, and the mode selected for stopping the motor (SFLSD[axis]). As such, a safety buffer should be included in any soft-limit settings.