SFLP – Positive Soft-limit setting
Gets/sets the [value] for the positive soft-limit on [axis].
Access: Read/Write
Category: Motion
Applies to: All Commander Controllers
ASCII SFLP[axis]
Syntax
Read
SFLP[axis]
|
[axis] is set to X, Y, Z, U |
Write
SFLP[axis]=[value]
|
[axis] is set to X, Y, Z, U [value] specifies target of positive soft-limit (28-bit value) |
Reply
Command is accepted and executed
Read
Returns the comparator value of the [axis] positive direction soft-limit (28-bit value)
Write
OK
Command cannot be processed
An error message is returned. See Error Codes
Example
Read
SFLPY * Returns the comparator value of the Y axis positive direction soft-limit
Write
SFLPX=8000 * Sets X axis positive direction soft-limit to 8000
Notes

- Before enabling soft-limits, check that softLimitPositive SFLP[axis] and softLimitNegative SFLN[axis] are different and that the positive value is greater than the negative value. If not, an error is returned.
- Soft-limits act similarly to limit switches. While the controller will command a stop when a soft-limit is encountered, it is possible to overrun the soft limit. The amount the system can overrun the limit depends on the speed the motor is moving at when the soft-limit is encountered, and the mode selected for stopping the motor (SFLSD[axis]). As such, a safety buffer should be included in any any soft-limit settings.