Gets/sets position [value] for [axis].


Access: Read/Write

Category: Motion

Applies to:  All Commander Controllers

ASCII/Standalone                P[axis]


Syntax

       

Read

P[axis]                

[axis] is set to X, Y, Z, U


Write

P[axis]=[value]                 

[axis]  is set to X, Y, Z, U

[value]  specifies the value to command pulse counter value (32-bit number)


Reply 

Command is accepted and executed


Read         

Returns the value of the command pulse counter value (32-bit number)


Write           

OK


Command cannot be processed

       An error message is returned. See Error Codes


Example 

Read        

PY                * Returns the command pulse counter value for the Y axis.

Write        

PX=2400         * Sets the command pulse counter to 2400 for the X axis.


Notes

None


See also

Motion Settings

D, EP, E, PP


Commander Manual

Output Pulse Counter