Gets/sets the limit correction [value] for [axis].


Access: Read/Write

Category: Motion

Applies to:  2ED, 2EX

ASCII                LCA

LCA[axis]=[value]


Syntax                

       

Read

LCA[axis]                

[axis] is set based on desired configuration mode from 1 - 8 (see chart below)


Write

LCA[axis]=[value]                 

[axis] is set based on desired configuration mode from 1 - 8 (see chart below)

[value]      specifies the limit value 32-bit range


Command

Description

LCA1

X-axis negative outer limit

LCA2

X-axis negative inner limit

LCA3

X-axis positive inner limit

LCA4

X-axis positive outer limit

LCA5

Y-axis negative outer limit

LCA6

Y-axis negative inner limit

LCA7

Y-axis positive inner limit

LCA8

Y-axis positive outer limit

Reply 

Command is accepted and executed


Read         

Returns parameter [value]


Write           

OK


Command cannot be processed

       An error message is returned. See Error Codes


Example 

Read        

LCA4                 * Returns the positive limit value of the X axis

Write        

LCA1=-1000000         * Sets the negative side limit value of the X axis to -1000000.


Notes

None


See also

Motion Settings


Commander Manual

Identification Number

Position Control