Starts the Z move operation for [axis].

Access: Write

Category: Motion

Applies to: All Commander Controllers 


ASCII                Z                

                

Syntax


Write

Z[axis][+/-]

[axis]   specifies the axis to move  X, Y, Z, U

[+/-]    specifies the move direction (+, -)
                       + moves in the direction where the command pulse counter counts up
                       - moves in the direction where the command pulse counter counts down


Reply 

Command is accepted and executed


Write           

OK


Command cannot be processed

       An error message is returned. See Error Codes


Example 

       Write        

ZX-        * Starts the Z move operation with the command pulse counter counts up for the X-axis


Notes

None


See also

Homing Settings

H, ZCNT, Z, ZH


Commander Manual

Z-move Operation