Gets/sets the n-position range [value] to use in StepNLoop for [axis].

Access: Read/Write

Category: StepNLoop

Applies to: All Commander Controllers


ASCII/Standalone                SLT[axis]


Syntax        

               

Read

SLT[axis]                

[axis] is set to X, Y, Z, U


Write

SLT[axis]=[value]                

[axis]  is set to X, Y, Z, U

[value]  is the positioning completion range value  (32-bit value)


Reply 

Command is accepted and executed


Read         

Returns the value of the positioning completion range value (32-bit value)


Write           

OK


Command cannot be processed

       An error message is returned. See Error Codes


Example 

Read        

SLTX                * Returns in-position range in pulses for the X axis

Write        

SLTZ=100         * Sets in-position range to 100 pulses from target position for the Z axis


Notes

  • The value for SLT should always be less than the value for SLE[axis].    
  • Joystick and buffer operation are invalid during StepNLoop operation.


See also

StepNLoop

SL, SLA, SLE, SLR, SLRA, SLS


Commander Manual

StepNLoop Closed Loop Control operation