Read/write command that returns/sets the enable status of each axes. 

EOBOOT – Axis Enable Status on Boot-up

Applies to: All Commander Controllers

ASCII                        EOBOOT                

Syntax

Read

       EOBOOT                

Write

       EOBOOT=[value]

Where:        [value]   is an integer [(0-3) for 2-axis, (0-15) for 4-axis, (0-255) for 8-axis] that represents the bit configuration of the boot enable output status.

See table in the Notes section for more details.

Reply

Command is accepted and executed

Read        

EOBOOT        returns an integer [(0-3) for  2-axis, (0-15) for 4-axis] that represents the bit configuration of the enable outputs

Write           

   OK

Command cannot be processed

       An error message is returned. See Error Codes                                                

Example 

Read        EOBOOT  * Returns  boot enable output status for all axes 

* Ex. Return a value of 9, or binary 1001, indicates axes X and U are enabled, 2 and 3         are disabled on boot up.        

Write        EOBOOT=11        * Since 11 is binary 1011, sets axes X, Y, and U as enabled, Z-axis as disabled on boot up.

Notes

  • Table for CMD-2CR

Bit

Axis Designation

Disabled, Enabled

0

X-axis

0            1

1

Y-axis

0            1

  • Table for CMD-4CR, CMD-4EX-SA

Bit

Axis Designation

Disabled, Enabled

0

X-axis

0            1

1

Y-axis

0            1

2

Z-axis

0            1

3

U-axis

0            1

  • Table for CMD-8CR

Bit

Axis Designation

Disabled, Enabled

0

X-axis

0            1

1

Y-axis

0            1

2

Z-axis

0            1

3

U-axis

0            1

4

A-axis

0            1

5

B-axis

0            1

6

C-axis

0            1

7

D-axis

0            1

See also