2.1.1.2 Synchronization with external trigger
It is possible to use an external trigger to start a defined motion profile. This is done by connecting the /CSTA pins as shown in the figure below. The /CSTA line needs an external pull-up resistor to VDD.
By default, the external start input is disabled (EXST=0), which will allow motion to start immediately upon receipt of any motion command. If the external start input is enabled (EXST=1), then any motion command sent will wait for the /CSTA input to go low before motion is started. The Commander core can buffer up to three movements on a first-in first-out order; they will start one at a time each time the /CSTA input goes low.
The logical input of the /CSTA input cannot be changed.