SYNWF – Synchronization Window Off
Enable the synchronization window for [axis].
Disables the synchronization window function. The synchronization function is not disabled, and the synchronization pulse continues to be output whenever the synchronization conditions are met, without limitation to position. There is no loss of synchronization from one pass to the next, and the synchronization function continues until SYNF[axis] is executed.
Access: Read/Write
Category: Sync
Applies to: 2CR, 4CR, 4ED, 4EX, CM3, 8CR
ASCII SYNWF[axis]
Syntax
Read
SYNWF[axis]
|
[axis] is the axis (X, Y, Z, U) |
Reply
Command is accepted and executed
Read
Returns the synchronization window status for specified axis
Write
SYNWF[axis]=[value]
|
[axis] is the axis (X, Y, Z, U) [value] is is the synchronization status 0: Disabled 1: Enabled |
Reply
Command is accepted and executed
Write
OK
Command cannot be processed
An error message is returned. See Error Codes
Example
Read
SYNWFX * returns the status of the synchronization window status for the X axis
Write
SYNWFX=1 * Enables the synchronization window on the X-axis.
Notes
The synchronization window function for each axis is independent.
See also
SYNC, SYNF, SYNO, SYNP, SYNS, SYNWO, SYNMAX, SYNMIN