Enable the synchronization window for [axis].


Disables the synchronization window function. The synchronization function is not disabled, and the synchronization pulse continues to be output whenever the synchronization conditions are met, without limitation to position. There is no loss of synchronization from one pass to the next, and the synchronization function continues until SYNF[axis] is executed.


Access: Read/Write

Category: Sync

Applies to: 2CR, 4CR, 4ED, 4EX, CM3, 8CR


ASCII                SYNWF[axis]


Syntax                

       

Read

SYNWF[axis]

[axis] is the axis (X, Y, Z, U) 


Reply 

Command is accepted and executed


Read         

Returns the synchronization window status for specified axis

 

Write

SYNWF[axis]=[value]

[axis] is the axis (X, Y, Z, U) 

[value] is is the synchronization status

0: Disabled

1: Enabled

 

Reply 

Command is accepted and executed


Write           

OK


Command cannot be processed

       An error message is returned. See Error Codes


Example 

Read        

SYNWFX        * returns the status of the synchronization window status for the X axis


Write        

SYNWFX=1         * Enables the synchronization window on the X-axis.


Notes

The synchronization window function for each axis is independent.


See also

I/O Setup, 

SYNC, SYNF, SYNO, SYNP, SYNS, SYNWO, SYNMAX, SYNMIN


Commander Manual

High-Speed Digital Output