Gets/sets the minimum [value] of the sync pulse window for [axis].


Reads the value of the synchronization window lower limit. This indicates the minimum encoder/pulse position to which the synchronization pulse can be output during continuous synchronization mode. Synchronization pulse is not output at encoder/pulse position with values lower than the set minimum (SYNMIN[axis]). The default value for SYNMIN[axis] is 0. Set the synchronization window lower limit by using SYNMIN[axis]=n.


Access: Read/Write

Category: Sync

Applies to: 2CR, 4CR, 4ED, 4EX, CM3, 8CR


ASCII                        SYNMIN[axis]


Syntax                        

Read

SYNMIN[axis]                

[axis] is set to X, Y, Z, U


Write

SYNMIN[axis]=[value]                 

[axis] is set to X, Y, Z, U

[value]           is the target value

* Valid values for n target value

Any value inside of the positioning control range (-134,217,728 to +134,217,727)  (28bit)        

SYNMIN[axis] must be smaller than SYNMAX[axis]


Reply 

Command is accepted and executed


Read         

Returns the current set value for the sync window lower limit (28-bit value)


Write           

OK


Command cannot be processed

       An error message is returned. See Error Codes


Example 

Enable the synchronization window and set min/max values.

SYNPX=1000

* 1000 counts between synchronization output pulses on the X-axis.

SYNCX=8

* Sets sync mode to continuous for X-axis, based on pulse position.

SYNMAXX=100000

* Sets the maximum value for the synchronization window to 100,000 on the X-axis.

SYNMINX=2000

* Sets the minimum value for the synchronization window to 2000 on the X-axis.

SYNWOX

* Enables sync output and synchronization window on the X-axis.


Notes

  • The synchronization window lower limit function is independent for each axis. 
  • The synchronization window function overlays the continuous synchronization mode. An error message will appear if the synchronization mode (SYNC[axis]) is not set to one of the continuous modes. 
  • The value set to SYNMIN[axis] must be within the positioning control range (-134,217,728 to +134,217,727) 28-bit
  • If SYNMIN[axis] is set to a positive value, SYNMAX[axis] should be set first.


See also

I/O Setup, 

SYNC, SYNF, SYNO, SYNP, SYNS, SYNWO, SYNWF, SYNMAX


Commander Manual

High-Speed Digital Output