PRG/END – Standalone PRG/END Command

The commands described here are only available when writing a standalone program.


In standalone programs, this command is used to define the beginning and end of a main program. All code is written between the PRG and END lines.


For 4 axis controllers, four (4) standalone programs are available.



Applies to: CMD-4CR, CMD-4EX-SA, PMX-4EX-SA, PMX-4ET-SA, PMX-2ED-SA, PMX-2EX-SA


Standalone                PRG [prg#]

                       ;main program

       END

Syntax                        

Write

PRG [prg#]                 

       [prg#] [0-3] for 4 axis controllers [CMD-4CR, CMD-4EX-SA, PMX-4EX-SA, PMX-4ET-SA]

                             

       END 

Reply 

Command is accepted and executed

No Reply

Example 

Write        

PRG 0                        * Program start line, program 0

HSPD=20000                * Set the high speed to 20000 pulse/sec

LSPD=500                * Set the low speed to 500 pulse/sec

;main program         * main program code.

END                         * End of program 0

Notes

  • If PRG number is not included then program is assigned to program 0.
  • If only one main program is used in the standalone, then PRG is not required.

See also

Standalone Programming Commands


Commander Manual

Identification Number