Sets the latch enable [value] for [axis].


Access: Write

Category: Latch

Applies to:  2CR, 4CR, 4ED, 4EX, CM3, 8CR

ASCII/Standalone                LT


Syntax        

               

Write

LT[axis]=[value]                 

[axis] is set to X, Y, Z, U

[value] enables or disables the latching function for [axis]

               0: disabled

               1: enabled


Reply 

Command is accepted and executed


Write           

OK


Command cannot be processed

       An error message is returned. See Error Codes


Example 

Write        

LTX=1         * Enables the latch function for X axis.


Notes

The LT[axis] is read to see the current enable status. 


See also

I/O Setup, 

LTE, LTP, LTS


Commander Manual