LT – Latch Enable
Sets the latch enable [value] for [axis].
Access: Write
Category: Latch
Applies to: 2CR, 4CR, 4ED, 4EX, CM3, 8CR
ASCII/Standalone LT
Syntax
Write
LT[axis]=[value]
|
[axis] is set to X, Y, Z, U [value] enables or disables the latching function for [axis] 0: disabled 1: enabled |
Reply
Command is accepted and executed
Write
OK
Command cannot be processed
An error message is returned. See Error Codes
Example
Write
LTX=1 * Enables the latch function for X axis.
Notes
The LT[axis] is read to see the current enable status.