Analog Inputs
|
Parameter |
Value |
|
Channels |
2 (AIN1 on J5.44, AIN2 on J5.48) |
|
Input range |
0 to 5 V |
|
Resolution |
12-bit |
|
Input impedance |
29.6 kΩ to ground |
|
Scaling |
10 kΩ / 19.6 kΩ divider to the converter input |
|
Reference |
Logic ground (J5.40) |
Not protected against overvoltage. The analog inputs reach the converter through a series resistor and a divider only. There is no clamp or transient suppressor. Do not exceed 5 V, and do not apply any voltage below ground.