HSO - High speed output
Below is the detailed schematic of the opto-isolated high speed digital output.
Schematic:
Notes:
The opto-supply (pin 9 of 10 pin I/O connector) must be connected to at least +12VDC, but not exceed +48VDC, in order for the digital outputs to operate.
Applies to:
10-PIN DIO connector (High speed Input/Output) Pins 1 to 4