Field Supply
The field side of the isolation barrier is powered entirely by the customer. Two independently fused positive rails are provided so that the limit/home group and the general-purpose group can be fed from separate supplies if wanted; they share one return.
|
Pin |
Name |
Function |
Rating |
|
J7.29 |
DI V+ |
Field supply for the general-purpose inputs and the outputs |
12–24 Vdc, 26.4 V max, fused 0.25 A |
|
J7.3 |
LIM V+ |
Field supply for the limit/home inputs |
12–24 Vdc, 26.4 V max, fused 0.25 A |
|
J7.30 |
FIELD GND |
Field ground, common return for both groups and for the outputs |
— |
Isolation depends on the field supply. The field domain is isolated from the logic domain only if the field supply is itself isolated from the logic supply. Use a separate supply, or an isolated output of the same supply. If the two share a return, the barrier is bypassed and no isolation remains.