The Digital IO screen provides information and configuration setting for digital inputs, digital outputs and PWM duty cycle settings.

Displayed information and settings for the Digital IO screen:

Digital Out – Status of digital output signal

      Digital output is triggered

                  Digital output is not triggered

The polarity of the outputs can be changed by clicking in the white or blue box to update.

Mode – Configuration for digital output (as an output or synced)

Digital In – Status of digital input signal

      Digital input is triggered

      Digital input is not triggered

Mode – Configuration for digital input (as an input or latched)

PWM 1 (%) – Setting for PWM1 output duty cycle, percent on

PWM 2 (%) – Setting for PWM2 output duty cycle, percent on