A.7 Homing Mode 6
Homing mode 6 uses the end of travel limit switch to trigger home location. The end limit is encountered and the motor reverses off the end of travel limit at a lower speed and sets home position.
Homing Mode |
Home Limit |
End Limits |
Z-index |
Slow Down |
Approaches Home at |
Direction to Trigger Zero |
Ending Point |
|
High Speed |
Low Speed |
|||||||
Mode 6 |
|
● |
|
○ |
H |
|
Reverse Dir |
Zero |
Operation 1:
- Homing operation is started, accelerate from LSPD to HSPD.
- Immediate stop when the end of travel limit switch is encountered.
- Reverse direction at LSPD until end limit switch turns off.
- Operation stopped immediately and homing operation is completed, zero position is set.
- ERC pulse is sent.
Note: When utilizing the end travel limits, the ERC command will clear the end-of-travel limit flag in the direction of the home during the homing operation. Refer to ERC command in the Command Reference for further details.