A.4 Homing Mode 3
Homing mode 3 uses both the home limit switch and Z-index pulse. The deceleration to the home set point occurs after the move passes through the home limit switch and encounters the Z-index pulse.
| Homing Mode | Home Limit | End Limits | Z-index | Slow Down | Approaches Home at | Direction to Trigger Zero | Ending Point | |
| High Speed | Low Speed | |||||||
| Mode 3 | ● |  | ● | ○ | H |  | Dir of Home | Non-Zero | 

Operation 1:
- Homing operation is started, accelerate from LSPD to HSPD.
- Continue moving at HSPD after home limit is encountered.
- Decelerate when specified number of Z-index pulses are counted (ZCNT), zero position is set.
- Operation decelerates and stops.
- ERC pulse is sent.
Operation 2:
- Homing is started while home input is activated.
- Acceleration from LSPD to HSPD.
- End limit is encountered, immediate stop.
Operation 3:
- Homing is started moving away from the home input switch.
- Acceleration from LSPD to HSPD.
- End limit is encountered, immediate stop.