This counter shows the total number of pulses that have been received on the encoder input.  It can be read using ASCII command EP, which returns the encoder counts of all 4 axes.  The return value has the following format:

[Encoder X]:[Encoder Y]:[Encoder Z]:[Encoder U]


The encoder count of each axis can also be accessed or set individually, by using the E[axis] command.