4.17 Encoder Input Connection
Both single-ended and differential quadrature encoder inputs are accepted.
When using single-ended encoders, use the /A, /B, and /Z inputs.
+5V supply and Ground signals are available to power the encoder. Make sure that the total current usage is less than 200mA for the +5V.