The Commander series of controllers has the communication port settings shown in table Serial port settings below.

Parameter

Setting

Byte Size

8 bits

Parity

None

Flow Control

None

Stop Bit

1

Serial port settings

Commander series of controllers provides the user with the ability to set the desired baud rate of the serial communication. In order to make these changes, first set the desired baud rate by using the DB command. By default, the Commander series of controllers has a baud rate setting of 9600 bps.

Return Value

Description

1

9600

2

19200

3

38400

4

57600

5

115200

DB command

To write the values to the device’s flash memory, use the STORE command. The new baud rate will now be written to memory, but will not go into effect until after a complete power cycle.